16000 Litre Horizontal Air Receiver

NS010576

11.5 Bar Design Pressure

2000mm Diameter with 4500mm Shell

Built to PD5500 – 2012 – CAT 2 from BS1501-224-490B/P355NL1/L2 (LT)

-10°C to 50°C and 1mm Corrosion Allowance

inspection by Lloyds Register with 10% Ultrasonics to code

PED Category CAT 4 modules G

Group 2 Gases

1 X Inlet

250NB BS4504 or EN1092 PN16 Flanged Branch WN

1 X Outlet

250NB BS4504 or EN1092 PN16 Flanged Branch WN

1 X Pressure Gauge

2″ BSPT 3000lb Screwed

1 X Drain Connection

1″ BSPT 3000lb Screwed

1 X Inspection Openings (s)

500NB BS4504 or EN1092 PN16 Flanged Branch Cover & Davit

2 X Supports

Cradles Support

2 X Other

Lifting Lugs

1 X Safety Valve

2″ BSPT 3000lb Screwed

1 X Signal Line

2″ BSPT 3000lb Screwed

1 X Top Vent

2″ BSPT 3000lb Screwed

Self Colour clean and dry with all openings sealed

Drawing Number (Orig)8673